Open Access Research article

Lack of change in urate deposition by dual-energy computed tomography among clinically stable patients with long-standing tophaceous gout: a prospective longitudinal study

Ashwin Rajan1, Opetaia Aati1, Ramanamma Kalluru1, Gregory D Gamble1, Anne Horne1, Anthony J Doyle2, Fiona M McQueen3 and Nicola Dalbeth1*

Author Affiliations

1 Bone and Joint Research Group, Department of Medicine, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Grafton, Auckland 1023, New Zealand

2 Department of Anatomy with Radiology, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Grafton, Auckland 1023, New Zealand

3 Department of Molecular Medicine, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Grafton, Auckland 1023, New Zealand

For all author emails, please log on.

Arthritis Research & Therapy 2013, 15:R160  doi:10.1186/ar4343

Published: 23 October 2013

Abstract

Introduction

Dual-energy computed tomography (DECT) has potential for monitoring urate deposition in patients with gout. The aim of this prospective longitudinal study was to analyse measurement error of DECT urate volume measurement in clinically stable patients with tophaceous gout.

Methods

Seventy-three patients with tophaceous gout on stable therapy attended study visits at baseline and twelve months. All patients had a comprehensive clinical assessment including serum urate testing and DECT scanning of both feet. Two readers analysed the DECT scans for the total urate volume in both feet. Analysis included inter-reader intraclass correlation coefficients (ICCs) and limits of agreement, and calculation of the smallest detectable change.

Results

Mean (standard deviation) serum urate concentration over the study period was 0.38 (0.09) mmol/L. Urate-lowering therapy was prescribed in 70 (96%) patients. The median (interquartile range) baseline DECT urate volume was 0.49 (0.16, 2.18) cm3, and change in DECT urate volume was -0.01 (-0.40, 0.28) cm3. Inter-reader ICCs were 1.00 for baseline DECT volumes and 0.93 for change values. Inter-reader bias (standard deviation) for baseline volumes was -0.18 (0.63) cm3 and for change was -0.10 (0.93) cm3. The smallest detectable change was 0.91 cm3. There were 47 (64%) patients with baseline DECT urate volumes <0.91 cm3. Higher serum urate concentrations were observed in patients with increased DECT urate volumes above the smallest detectable change (P = 0.006). However, a relationship between changes in DECT urate volumes and serum urate concentrations was not observed in the entire group.

Conclusions

In patients with tophaceous gout on stable conventional urate-lowering therapy the measurement error for DECT urate volume assessment is substantially greater than the median baseline DECT volume. Analysis of patients commencing or intensifying urate-lowering therapy should clarify the optimal use of DECT as a potential outcome measure in studies of chronic gout.